HSF / HSG Series HeatSink dryers incorporate ZEKS True-Cycling operation that cycles the dryer refrigeration system on and off in response to variations in compressed air demand. Combined with a low pressure drop design, this results in exceptional energy efficiency for supplying high quality compressed air.
This product price is available on request only
Overview | In response to compressed air system demand, the dryer refrigeration system automatically cycles on and off to cool a thermal storage media. This media is circulated through a ZEKS all-stainless steel CFX media-to-air heat exchanger, thereby cooling the compressed air and delivering dry air to the compressed air system. Condensed moisture is efficiently removed from the air stream via an automatic condensate drain. 14 Models, 150-2,400 SCFM |
Standard Features |
|
Optional Features |
|
Model | Capacity* (SCFM 38°F) | Pressure Drop** | Overall Dimensions | Ship Weight (lbs)
| Air Connect in/out | Drain Connect | Refig Comp
| Operating KW*** | Operating KW*** | Refrig Type | Max Working Pressure | Voltages § | ||||
|
|
| W (in) | D (in) | H (in) | Air-Cool Lbs. | Water-Cool Lbs. |
|
| Air-Cooled HP | Water-Cooled HP | Air-Cooled | Water-Cooled |
|
| |
150HSG | 150 | 2.6 | 14 | 35 | 31 | 300 | NA | 1 1/2" MPT | 1/4" | 1.0 | NA | 1.3 | NA | R404 | 300psig | 115-1-60 208/230-1-60 220-1-50 |
200HSG | 200 | 1.6 | 28 | 30 | 58 | 620 | 540 | 1 1/2" MPT | 1/4" | 1.0 | 1.0 | 2.1 | 1.1 | R404 | 300psig | 208-3-60 230-3-60 220-3-50 460-3-60 380-3-50 575-3-60
(230-3-60 not available on 2000-2400 models) |
250HSG | 250 | 2.7 | 28 | 30 | 58 | 670 | 570 | 1 1/2" MPT | 1/4" | 1.5 | 1.5 | 2.3 | 1.4 | R404 | 300psig | |
300HSG | 300 | 2.9 | 28 | 30 | 58 | 735 | 630 | 2" MPT | 1/4" | 2.0 | 2.0 | 2.8 | 1.7 | R404 | 300psig | |
400HSG | 400 | 2.9 | 28 | 30 | 58 | 745 | 670 | 2" MPT | 1/4" | 2.5 | 2.5 | 3.3 | 2.2 | R404 | 300psig | |
500HSF | 500 | 2.9 | 42 | 40 | 62 | 1105 | 1120 | 3" MPT | 1/4" | 4.0 | 4.0 | 5.0 | 3.2 | R404 | 300psig | |
600HSF | 600 | 3.0 | 42 | 40 | 62 | 1275 | 1270 | 3" MPT | 1/4" | 4.0 | 4.0 | 5.0 | 3.2 | R404 | 300psig | |
700HSF | 700 | 2.7 | 42 | 40 | 62 | 1320 | 1300 | 3" MPT | 1/4" | 4.5 | 4.5 | 6.1 | 3.6 | R404 | 300psig | |
800HSF | 800 | 2.9 | 42 | 40 | 62 | 1415 | 1300 | 3" MPT | 1/4" | 5.0 | 5.0 | 6.7 | 4.2 | R404 | 300psig | |
1000HSF | 1,000 | 2.5 | 32 | 72 | 69 | 2315 | 2355 | 4" FLG | 1/4" | 6.5 | 5.0 | 8.9 | 5.5 | R404 | 220psig | |
1200HSF | 1,200 | 3.1 | 32 | 72 | 69 | 2435 | 2435 | 4" FLG | 1/4" | 8.0 | 6.0 | 10.5 | 6.9 | R404 | 220psig | |
1600HSF | 1,600 | 3.3 | 32 | 72 | 69 | 2785 | 2615 | 4" FLG | 1/4" | 10.5 | 8.0 | 13.1 | 7.7 | R404 | 220psig | |
2000HSF | 2,000 | 3.5 | 32 | 91 | 91‡ | 3925 | 3925 | 6" FLG | 1/4" | 13.0 | 10.5 | 13.5 | 10.4 | R404 | 220psig | |
2400HSF | 2,400 | 3.5 | 32 | 91 | 91‡ | 4150 | 4015 | 6" FLG | 1/4" | 13.0 | 10.5 | 15.8 | 11.4 | R404 | 220psig |
* Performance data obtained as per ISO 7183, Table 2, Option A2.
Pressure dew point at 100 psig inlet air pressure, 100°F inlet air temperature, 100oF ambient air temperature.
** Pressure drop +-.5 psi
*** Average kilowatts per hour of dryer operation at full rated capacity
200-400 scfm units equipped with CMETM Cold Mist Eliminator limited to drain rating of 230 psi.
‡ Air-cooled dimension. Water-cooled dimension 76.12”
§ 200HSG also available in 208-1-60 and 230-1-60 voltages
NEMA 1 electrical enclosures standard.
Dimensions subject to change without notice.
Standard 150-800 scfm models ETL-Certified
1000-2400 models UL 508 Panels.
NA indication = Not Applicable
Protected under U.S. Patent Nos. 6,186,223 and 6,244,333
Overview | In response to compressed air system demand, the dryer refrigeration system automatically cycles on and off to cool a thermal storage media. This media is circulated through a ZEKS all-stainless steel CFX media-to-air heat exchanger, thereby cooling the compressed air and delivering dry air to the compressed air system. Condensed moisture is efficiently removed from the air stream via an automatic condensate drain. 14 Models, 150-2,400 SCFM |
Standard Features |
|
Optional Features |
|
Model | Capacity* (SCFM 38°F) | Pressure Drop** | Overall Dimensions | Ship Weight (lbs)
| Air Connect in/out | Drain Connect | Refig Comp
| Operating KW*** | Operating KW*** | Refrig Type | Max Working Pressure | Voltages § | ||||
|
|
| W (in) | D (in) | H (in) | Air-Cool Lbs. | Water-Cool Lbs. |
|
| Air-Cooled HP | Water-Cooled HP | Air-Cooled | Water-Cooled |
|
| |
150HSG | 150 | 2.6 | 14 | 35 | 31 | 300 | NA | 1 1/2" MPT | 1/4" | 1.0 | NA | 1.3 | NA | R404 | 300psig | 115-1-60 208/230-1-60 220-1-50 |
200HSG | 200 | 1.6 | 28 | 30 | 58 | 620 | 540 | 1 1/2" MPT | 1/4" | 1.0 | 1.0 | 2.1 | 1.1 | R404 | 300psig | 208-3-60 230-3-60 220-3-50 460-3-60 380-3-50 575-3-60
(230-3-60 not available on 2000-2400 models) |
250HSG | 250 | 2.7 | 28 | 30 | 58 | 670 | 570 | 1 1/2" MPT | 1/4" | 1.5 | 1.5 | 2.3 | 1.4 | R404 | 300psig | |
300HSG | 300 | 2.9 | 28 | 30 | 58 | 735 | 630 | 2" MPT | 1/4" | 2.0 | 2.0 | 2.8 | 1.7 | R404 | 300psig | |
400HSG | 400 | 2.9 | 28 | 30 | 58 | 745 | 670 | 2" MPT | 1/4" | 2.5 | 2.5 | 3.3 | 2.2 | R404 | 300psig | |
500HSF | 500 | 2.9 | 42 | 40 | 62 | 1105 | 1120 | 3" MPT | 1/4" | 4.0 | 4.0 | 5.0 | 3.2 | R404 | 300psig | |
600HSF | 600 | 3.0 | 42 | 40 | 62 | 1275 | 1270 | 3" MPT | 1/4" | 4.0 | 4.0 | 5.0 | 3.2 | R404 | 300psig | |
700HSF | 700 | 2.7 | 42 | 40 | 62 | 1320 | 1300 | 3" MPT | 1/4" | 4.5 | 4.5 | 6.1 | 3.6 | R404 | 300psig | |
800HSF | 800 | 2.9 | 42 | 40 | 62 | 1415 | 1300 | 3" MPT | 1/4" | 5.0 | 5.0 | 6.7 | 4.2 | R404 | 300psig | |
1000HSF | 1,000 | 2.5 | 32 | 72 | 69 | 2315 | 2355 | 4" FLG | 1/4" | 6.5 | 5.0 | 8.9 | 5.5 | R404 | 220psig | |
1200HSF | 1,200 | 3.1 | 32 | 72 | 69 | 2435 | 2435 | 4" FLG | 1/4" | 8.0 | 6.0 | 10.5 | 6.9 | R404 | 220psig | |
1600HSF | 1,600 | 3.3 | 32 | 72 | 69 | 2785 | 2615 | 4" FLG | 1/4" | 10.5 | 8.0 | 13.1 | 7.7 | R404 | 220psig | |
2000HSF | 2,000 | 3.5 | 32 | 91 | 91‡ | 3925 | 3925 | 6" FLG | 1/4" | 13.0 | 10.5 | 13.5 | 10.4 | R404 | 220psig | |
2400HSF | 2,400 | 3.5 | 32 | 91 | 91‡ | 4150 | 4015 | 6" FLG | 1/4" | 13.0 | 10.5 | 15.8 | 11.4 | R404 | 220psig |
* Performance data obtained as per ISO 7183, Table 2, Option A2.
Pressure dew point at 100 psig inlet air pressure, 100°F inlet air temperature, 100oF ambient air temperature.
** Pressure drop +-.5 psi
*** Average kilowatts per hour of dryer operation at full rated capacity
200-400 scfm units equipped with CMETM Cold Mist Eliminator limited to drain rating of 230 psi.
‡ Air-cooled dimension. Water-cooled dimension 76.12”
§ 200HSG also available in 208-1-60 and 230-1-60 voltages
NEMA 1 electrical enclosures standard.
Dimensions subject to change without notice.
Standard 150-800 scfm models ETL-Certified
1000-2400 models UL 508 Panels.
NA indication = Not Applicable
Protected under U.S. Patent Nos. 6,186,223 and 6,244,333
Rent product
Interested in renting ZEKS - HSG/HSF Series Compressed Air Dryer? Please fill in the form below and we will get back to you in the shortest time.